• Unity Suite
  • Solutions
    Local SCADA, EMS & PPC

    Locally control and monitor your renewable assets in real time with Local SCADA, Local EMS, and Power Plant Controller (PPC) solutions.

    Central SCADA & EMS

    Central SCADA and Central EMS solutions to provide portfolio-level control and monitoring across assets.

    Asset Performance Management

    Optimize asset availability and yield at scale with sophisticated monitoring, analysis, and intuitive workflows.

    AI Insights

    Leverage AI-powered analysis and recommendations for solar, wind, storage, and hybrid assets.

    Field Service Management

    Optimize field service through work order management, personnel scheduling, inventory management and maintenance KPIs.

    Asset Oversight

    Portfolio-level view of assets to provide a comprehensive system of record and enable oversight of operations, service providers, and revenue.

    Invoice Management

    Centralized and automated management of invoices to enable cashflow management, streamlined reporting, and accurate financial management.

  • Resources
    Blog

    Read recent blog posts and thought leadership from our experts.

    Resource library

    Access our library of e-books, white papers, and product sheets from our experts.

    Customer stories

    Read success stories and testimonials from our customers.

  • About
    Meet our team

    Learn more about our vision and values and meet our executive leadership team.

    Careers

    Interested in joining our team? See open positions.

    Contact us

    Get in touch with the Power Factors team.

    Events

    Connect with us at industry events and join our upcoming webinars.

    Newsroom

    Check out Power Factors' latest news and press releases.

  • Get a demo

Power Factors’ EMS supports complex hybrid off-grid power system at gold mine

Power Factors’ Local EMS (Energy Management System) has been successfully deployed to manage a complex hybrid off-grid power system at a gold mine, enabling the integration of renewable energy sources into its operations.

solar and battery energy storage
In this article

Power Factors’ Local EMS (Energy Management System) has been successfully deployed to manage a complex hybrid off-grid power system at a gold mine, enabling the integration of renewable energy sources into its operations. The system integrates a 34 MW photovoltaic solar plant and an 18 MWh battery energy storage system (BESS) with several heavy fuel oil (HFO) generators and is projected to reduce greenhouse gas emissions by over 500 kilotons throughout the mine’s lifetime.   

AdobeStock_298421739

Already in operation for nearly a year, the EMS’s primary goal is to maximize solar energy penetration while maintaining the minimum technical load of the HFO units and ensuring grid stability. Although the BESS acts as a buffer by injecting or absorbing power as needed, cloudy skies can still pose stability challenges. That’s where the EMS steps in, playing a critical role in improving overall system performance and penetration limits while ensuring consistent power quality and secure load supply.

To enhance the system's performance during cloud events, a weather forecasting system (WFS) based on cloud cameras was installed onsite. The WFS informs the EMS about sudden fluctuations (short, medium, and long-term) in PV production. The short-term WFS detects nearby clouds, measures cloud cover, locates cloud shadows, and predicts their future movement. With forecast times ranging from 30 seconds to 30 minutes, the WFS helps manage ramp rates and spinning reserves, optimizing control of the off-grid system under varying solar conditions. This also protects the HFO units, as rapid, uncontrolled fluctuations in intermittent PV generation could damage their mechanical components. 

AdobeStock_400752197

While the HFO generators serve as the main grid-forming elements of the hybrid system, the BESS is also configured to operate in grid-forming mode as a voltage source alongside the HFO units, enabling seamless transitions to islanding mode when necessary. Additionally, the BESS functions as a primary frequency response element, performing frequent micro-cycles to maintain frequency stability close to the reference value. 

Power Factors’ Local EMS also conducts dynamic and static load shedding to ensure system stability. Load shedding occurs when there is insufficient reserve capacity to meet demand, causing power to be automatically disconnected from certain predefined consumers in order to balance electricity supply and demand.

As with all assets managed by Power Factors, we continuously support the system, the independent service provider (ISP), and the owner in their efforts to maintain a reliable off-grid electrification system while achieving fuel savings of approximately 180 million liters over the asset's lifetime. 

To learn more about Power Factors’ local monitoring and controls, get in touch! 

End-to-end solutions across the entire renewable asset lifecycle

We provide the world’s most comprehensive product suite — purpose-built for renewable energy assets.

Optimize assets, maximize revenue, and grow your portfolio with Unity

Ready to experience the future of renewable energy management?
Group 2277